DC 12V
DC 24V
Features:
- Applicable to 6-way hydraulic solenoid directional valve
- With threaded connection, the coil can be replaced without shutdown
- Equipped with manual emergency device
- Coil inner hole φ23
Outline and connection dimensions:
technical parameter |
||
Ambient temperature |
℃ |
-25~50 |
Voltage fluctuation range |
% |
85~110 |
Rated power |
W |
30 |
Rated stroke |
mm |
3 |
Full stroke |
mm |
≥6.1 |
Working oil pressure |
Mpa |
≤21 |
Degree of protection |
IP65 |
|
Operating frequency |
T/h |
12000 |
Power on duration |
% |
100 |
Insulation class |
H(180) |
|
Electrical connection mode |
DT04-2P |
Matters needing attention:
1. The coil shall not be powered on alone, which has the risk of burning!
2. Non explosion-proof coil shall not be used in medium with explosion risk!
3. After the coil is installed, it must be grounded reliably, otherwise there is a risk of electric shock!